Product Category
Ring wave simulator
  • Ringing wave immunity
    Ringing wave immunity
    IEC 61000-4-12

    HRWS - EN.pdf

    HRWS 71

    Ringing wave immunity system conforms to IEC 61000-4-12  


    ◆ Output voltage :(0.2KV-7.0KV)±10%

    ◆ Oscillation frequency: 100KHz

    ◆ Polarity: positive/negative/positive and negative alternately

    ◆ Repeat frequency: maximum 60 times/min

    ◆ Output impedance: 12 Ω / 30 Ω

    ◆ Interval time: 1S-9999s

    ◆ Voltage rise time: 0.5μs + 30%(open circuit)

    ◆ Current rise time: ≤1μs(short circuit)

    ◆ Touch screen: 7 "800 x 480 24 bits

    ◆ Attenuation rate:

    0. 4 < Pk2 / railway < 1.1

    0. 4 < Pk3 / Pk2 < 0.8

    0. 4 < Pk4 / Pk3 < 0.8

    ◆ Size: 4 8 2 m m X 5 5 6 m m X 3 6 5 5 m m

    ◆ Coupling/decoupling network: built-in single-phase 16A


  • HRWS 100

    Ringing wave immunity system conforms to IEC 61000-4-12  


    ◆ Output voltage :(0.5KV-10.0KV)±10%

    ◆ Oscillation frequency: 100KHz

    ◆ Polarity: positive/negative/positive and negative alternately

    ◆ Repeat frequency: maximum 60 times/min

    ◆ Output impedance: 12 Ω / 30 Ω

    ◆ Interval time: 1S-9999s

    ◆ Voltage rise time: 0.5μs + 30%(open circuit)

    ◆ Current rise time: ≤1μs(short circuit)

    ◆ Touch screen: 7 "800 x 480 24 bits

    ◆ Attenuation rate:

    0. 4 < Pk2 / railway < 1.1

    0. 4 < Pk3 / Pk2 < 0.8

    0. 4 < Pk4 / Pk3 < 0.8

    ◆ Size: 4 8 2 m m X 5 5 6 m m X 3 6 5 5 m m

    ◆ Coupling/decoupling network: built-in single-phase 16A


  • RCDN 161P

    Single-phase coupling decoupling network conforms to IEC 61000-4-12  


    ◆ Coupling pulse: >=±10.0kV

    ◆ EUT power supply voltage: 2× 250VAC

    ◆ Continuous current: 16A

    ◆ Conforming with IEC 61000-4-12 and ANSI Only for HRWS


  • HCOUPLER 16R / 30R / 60R / 100R / 200R

    Three-phase coupling decoupling network conforms to IEC 61000-4-12  


    ◆ Coupling pulse: maximum ±7kV

    ◆ EUT power supply voltage: 3× 480VAC

    ◆ Continuous current: 16A / 32A / 64A / 100A / 200A

    ◆ Decoupling inductor: 4× 1.5MH

    ◆ Conforming with IEC 61000-4-12 and ANSI


1page|2page|4item/page|8item   [first][Previous] [next][last]